The washing machine adopts mechanical arms to clamp the containers, suitable for ampoules of 1-20ml and vials of 2-30ml;
The water-gas spray nozzles adopt the reciprocating tracking insertion mode for container washing, featured by excellent washing effect and energy saving. It is also provided with a device that prevents the nozzle holder from shaking to enhance the accuracy of the spray nozzle's insertion into the container and reduce the occurrence of nozzle breakage;
The water and gas pipes are totally separable from the spray nozzles, so that cross contamination is avoided and cGMP requirements are met;
The spray nozzle guide mouth of the container washing machine adopts imported ceramic bushing without wear;
Container out-feed is realized by the integral imported synchronous belt that is connected to the container pushing block to convey ampoules, a structure that ensures stable and reliable operation;
The depyrogenation tunnel adopts the hot air circulation heating method with even temperature and energy saving;
The depyrogenation tunnel is provided with the function of protecting against sudden power-off to ensure safe running;
The depyrogenation tunnel can be equipped with the water cooling device that does not consume air volume in the room, whilst reducing the risk of unbalanced differential pressure in the room and achieving good cooling effect;
The depyrogenation tunnel can be equipped with the differential pressure automatic balancing and regulating system to reduce the problems of deviation at the high temperature section caused by unbalanced differential pressure in the room and tunnel, temperature rise in the filling room and washing-drying room;
The depyrogenation tunnel is provided with PAO inspection ports (including inspection ports for air pressure, air speed and dust particles);
The cooling section in the tunnel is provided with the sterilization function (specially chosen by FDA).
The depyrogenation tunnel mesh belt can be equipped with the ultrasonic and CIP cleaning systems;
The depyrogenation tunnel chamber can be subject to all-round, multi-angle high pressure water washing;
The filling and closing machine can be used for ampoule filling, vial filling and full-stoppering, and vial filling and half-stoppering;
The filling and closing machine is provided with sufficient gas purging work stations to ensure one-off purging and the completion of the procedures of pre and post fill nitrogen purging and full/half stoppering;
The filling and closing machine is provided with the functions of no bottle no filling and no bottle no stoppering;
The filling machine can be equipped with the servo filling system.
Control system of brands such as Siemens, Schneider, Allen Bradley, Mitsubishi and Delta;
Online particle counting, alarm system, recording and printing systems;
ORABS, CRABS, or aseptic isolator system.
Product Model | QCL80+ASMR620/48+KAGF8 | QCL20+ASMR620/48+KAGF10 | ||
Applicable Specifications (ml) | Vial: 2-30 | Ampoule: 1-20 | Vial: 2-10 | Ampoule: 1-20 |
Capacity (pcs/h) | 6,000-18,000 | 6,000-23,000 | 8,000-20,000 | 8,000-28,000 |
Clarity (%) | >99 | |||
Qualified Rate of Stoppering (%) | >99 | |||
Fresh Water Consumption (m3/h) and Pressure (mpa) | Consumption: 0.4-1.0 Pressure: 0.2-0.3 |
|||
Purified Compressed Air Cosumption (m3/h) and Pressure (mpa) | Consumption: 30-75 Pressure: 0.2-0.3 |
|||
Sterilizing Temperature (°C) | 30-50 | |||
Exhaust Volume (m3/h) | 500 | 900 | 500 | 900 |
Cleanliness of Laminar Air (Class) | 100 | |||
Gas Fuel Consumption (m3/h) and Pressure (mpa) | / | Consumption: 1.5-2.5 Pessure: 0.2-03 |
/ | Consumption: 1.5-2.5 Pessure: 0.2-03 |
Oxygen Consumption (m3/h) and Pressure (mpa) | / | Consumption: 1.2-1.5 Pressure: 0.2-0.3 |
/ | Consumption: 1.2-1.5 Pressure: 0.2-0.3 |
Speed of Vacuum Pumping | 20 | / | 20 | / |
Dimension (LxWxH) (mm) | 100 | |||
Weight (kg) | 7,500 | |||
Power Capacity (kw) | 380V/50Hz, 71kw |